Daily well readings and production volumes

Pumpers key tank levels, tubing and casing pressures, run hours and exceptions for each wellhead and battery on a tablet or handset. The office reads daily volumes by well and facility from those entries. Gaps are visible. A well without a reading stays on the route sheet until someone enters it.

What a reading sheet records for each site

A reading sheet is built for the type of site, so a pumper is asked only for what that site has. A wellhead, a tank battery and a compressor station each get their own. Units stay as entered. Barrels, thousand cubic feet and psi are not converted.

Tank levels and volumes

Each tank on a wellhead or battery sheet takes a level in the unit your engineers use, such as barrels. Daily volumes by well and facility are built from those entries. Units stay as typed.

Tubing and casing pressures

Tubing and casing pressures are keyed in psi against the well, beside the date and the name of the person who entered them. A pressure that drifts from one day to the next shows in the sequence. Nobody waits for month end.

Run hours on machines

Run hours are taken from compressors and pumpjacks that carry a meter, and they sit on the machine record. Servicing set by run hours reads them from here. The due date moves with the machine.

Exceptions and notes

An exception is entered where the pumper finds it, such as a leaking gland, a stuck valve or a tank near its top. The note stays with the reading and the well. A job can be raised from it.

A route through the pads, from first light

A route is the list of wells and facilities one pumper visits in a round. The sheet follows that list. The office watches it fill. Four moments from a day in the field and the office show it at work.

At the first wellhead

A pumper opens the route on a tablet, stands at the first wellhead and keys the tank level, then the tubing and casing pressures. The sheet moves to the next well. Every entry carries the well and the date.

A pad out of range

A remote pad has no signal. Entry runs through a browser, so the pumper keys that pad’s readings once back in range. Until then the route sheet shows the well as outstanding, and the office can see why.

The clerk at midday

A production clerk opens the list of wells and routes with readings missing. One route is half done. The clerk rings that pumper, asks where the round has reached and learns whether a gate or a breakdown held it up.

The manager reading volumes

An operations manager opens daily volumes by well, battery and facility. A well that looks low against its neighbours on the pad draws attention. The manager checks pressures and run hours first. A crew is sent after that.

Who keys the figures and who reads them

The people who enter readings are rarely the people who study them. Each group gets its own view. All of them are built from the same entries made at the wellhead.

Pumpers and field operators

Pumpers follow a route, enter readings and exceptions at each wellhead and raise a job when a pumpjack, a tank or a line needs attention. The screen lists only that round. Nothing else clutters it.

Operations managers reading volumes

Operations managers read wells reported, daily volumes and the wells and routes with readings missing. A tile compares wells reported with wells on the route. Open exceptions sit beside the volumes. Missing routes stand out.

Planners setting servicing

Planners read run hours from the daily entries and use them to set servicing. A compressor near its run-hour limit moves up. Pressure notes from pumpers tell them where to look first when a pad looks wrong.

Accountants reading volumes by well

Accountants read volumes by well beside the costs charged to it. Partners who receive statements expect both figures to agree with the field. Daily entries give that agreement a firm base. Gaps are chased early.

Decisions to settle before readings start

The reading sheet is only as good as the questions it asks. Four decisions are best made with the pumpers themselves, since they know which gauges stick and which pads are hard to reach. Make them before the first route goes live.

Who may correct a reading for daily readings and production

Pumpers will mistype a pressure now and then. Decide who may change a saved reading and whether a note must explain why. Tell pumpers who to ask. Without a rule, corrections arrive by phone and nobody records them.

Which sites get a sheet

List the sites that carry a sheet and those that do not. A shut-in well may need no daily entry. Write down the sites left out, so a blank on the screen is understood as a choice and not as a missed round.

How earlier readings come across for daily readings and production

Spreadsheet import is available. Earlier readings can be offered for it, and your team agrees with GullySystem which months of history are worth bringing in. Old paper route sheets may simply stay in the cabinet.

Which report matters first for daily readings and production

Begin with the list of wells and routes with readings missing. It shows whether pumpers have taken to the tablets. Daily volumes by well follow once entries settle. Pick one report to start, and let the others wait.

What readings hand to the rest of the product

Readings are not a stand-alone log. The figures keyed at the wellhead are read again by other features in the product. Each hand-off removes a piece of retyping at the office, and each starts from the same entry. Five of them are listed in the lines below.

  • Run hours move equipment servicing due dates
  • Exceptions become service jobs with a crew
  • Daily volumes sit beside costs charged to each well
  • Partner statements read volumes for each well and period
  • Gauge and sensor feeds can supply entries by arrangement

Where daily readings stop

This feature records and reports. It does not control equipment, and it does not run allocation calculations or reservoir models. Your SCADA, historian and engineering tools keep that work. It also cannot take entries while a handset has no connection. A single owner who checks one gauge a week may be content with a notebook.

FAQ

Frequently asked questions

Which units does a pumper enter readings in?

Your engineers’ own units, as used in the field today. Barrels, thousand cubic feet and psi stay exactly as entered. Each site type’s sheet is set up in that language. Nothing is converted behind the pumper’s back.

What shows when a pumper skips a well?

The route sheet lists the well as outstanding. Operations staff also read a report of wells and routes with readings missing. Someone out of range simply enters the figures later, once reconnected. The gap is visible to everyone.

Do run hours entered here set maintenance dates?

Yes, run hours do. Hours come from the daily reading, so the due date for a compressor moves with the machine. Servicing set by a calendar interval, as for a separator, does not depend on the reading at all.

Can sensor readings replace keyed entries?

Gauge and sensor feeds are an optional integration, priced as separate parts and agreed during scoping. Sites without a feed keep keyed entry. Both kinds can sit on the same route sheet without any special handling.

Can we see one well’s history of pressures?

Yes, by date. Entries are kept against the well with their dates, so a planner or manager can read the sequence. A drifting tubing pressure is then noticed sooner than it would be from paper sheets.

Where it fits

How this feature fits the system.

Oil and Gas Company Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.

Wells, pads and facilities

Each well, tank battery and compressor is listed with its equipment, location label and ownership interest, so costs and readings belong to a named asset.

Fixed Asset Register

Field tickets and service jobs

A treatment or workover is raised as a job with its crew, and the signed ticket records hours, equipment and chemical used.

Work Order Management

Equipment and preventive maintenance

Servicing for pumps, compressors and separators is scheduled by run hours or date, and each repair is kept on the machine record.

Asset AMC Tracking
Talk to us

Tell us what you need.

Tell us what your team does today, where work gets stuck and what you want to change.

What happens after you share your requirements

  1. We review your brief and the systems you already use.
  2. We clarify the workflow, missing information and the work to consider first.
  3. The proposed scope sets out the deliverables, responsibilities and dependencies.
  4. Review the scope and commercial terms before deciding whether to proceed.

Start with your requirements

Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.

Share your requirements