Skip to main content
GullySystem
A practical guide

How to Automate an AC Service Business

Ganesh HSStrategy and Technology, GullySystem
Practical advice · 4 min read

In this guide 7 sections
The short answer

Open with a single record for each customer site. List every AC unit installed there. Run installations, contract visits and breakdown calls from that record, so job sheets, gas stock, tax invoices and renewal lists follow from the same visits. Everyone then reads one shared history.

Start with sites and the units at each site

Units matter more than customers. A customer may own one flat or six shops, and each site can hold units of different brands, tonnages and ages, so the unit is the thing to record.

Record each customer first, then each site under that customer, then every unit at the site with its model, capacity, serial number and installation date. Every job is written against a unit. The history stays put.

Customer lists and unit details sit in a spreadsheet or paper register, and both can be imported after the coordinator checks the rows for duplicates. Retire the old register after that.

Put installations, contracts and breakdowns on one schedule

Most AC offices run installations, annual contract visits and breakdown calls, and all three compete for the same technicians, so they belong on one schedule.

A quotation lists units, piping, stands, electrical points and labour, and on acceptance it becomes an installation job with a team, a date and a materials list. Contract visits are set per unit. Breakdown calls arriving by phone, WhatsApp or the website are logged once, in the same queue, with the unit and fault noted by whoever answers.

The coordinator assigns each job by area and by the load already planned, and a technician finishing early can be sent to the nearest open breakdown call.

  • Quotations for units, piping and labour
  • Installation jobs with team and date
  • Contract visits scheduled per unit
  • Breakdown calls tracked to closure

Let the technician’s phone close each visit

A visit counts when recorded. On the phone, the technician sees the day’s visits, the units at each site and the fault history of every unit.

The job sheet takes the fault, the pressure readings, the work done, the gas added and the parts fitted, and the customer signs on screen before the technician leaves. Stock falls as work is done.

Brand warranty rides on the same sheet. A unit under warranty is marked, a replaced part is recorded against the visit, and the claim is followed until the manufacturer’s credit arrives.

Connect stock, invoices and renewals to the visits

Gas, compressors, capacitors, PCBs, fan motors and copper pipe sit in a store and in each vehicle, and every item fitted is deducted from the place it was issued.

Invoices come from recorded jobs. A visit can be marked as covered by a contract or warranty, and unpaid invoices are listed by customer for the accounts clerk to chase.

Contracts nearing their end date and units due for service are listed ahead of the season, and reminders reach customers by WhatsApp, text or email before the rush begins.

When a diary and a phone call are still enough

One technician who repairs on phone calls and sells no annual contracts can run on a diary, since a handful of calls a day needs no scheduling.

Three things decide it. They are the number of technicians, whether annual contracts are sold, and whether warranty claims are handled, and one yes is reason enough for unit records.

The HVAC and AC Service Management Software is configured around the contract terms, the service checklists and the warranty rules a business already follows, so staff keep their routine.

Put the advice to work.

Use a test copy or fictional example to turn the discussion into something your team can check.

Connect stock, invoices and renewals to the visits

Can you explain the balance from its original documents?

Select a partly settled example in “Connect stock, invoices and renewals to the visits”. Ask for the invoice, allocated receipts and remaining balance to be shown together before agreeing the opening figures.

Background reading: ERPNext: outstanding invoices

Unit and contract register

One line per AC unit carrying customer, site, model, serial number, installation date, contract end date and last service date. Fill it for ten customers. Blank cells show which fields a unit record must hold before scheduling can start, and which customers need a site visit to complete them.

Open a blank worksheet to print

Questions owners ask

What should be set up first when moving an AC business to software?

Enter customers, sites and units first, because every job, contract and invoice is written against a unit, then add contract end dates and open breakdown calls. Logins and checklists come last.

Can installation, service contracts and breakdown calls all run in one system?

Yes, as separate job types on one schedule, so an installer with no contracts can start with installation jobs and breakdown calls alone and add contract visits later.

Does the old gas and parts stock need counting before the first job?

Count the store and each vehicle once, record the quantities by item, and the system deducts from those opening figures as visits are closed. Skip this and stock reports will drift.

Browse all guidesBack to top ↑
Next step

Have a specific situation to work through?

This article covers the general case. Tell us what you’re actually dealing with and we’ll respond directly.

See the HVAC and AC Service Management Software product