Run analyser builds, firmware, burn-in, calibration points and field service on one serial record.
One serial follows an analyser, patient monitor or ultrasound unit from its first populated PCB to a pump swap years later in a hospital laboratory. It holds sensor and IC lots, the firmware image, heat chamber hours, calibration points against a named reference standard, the signed final test sheet and the installation report. Four departments, one record.
- Instrument models, bills and calibration sheets entered as you build
- Installed base and open service jobs migrated
- Changes to test sheets made by GullySystem staff when asked
A service engineer about to quote a lamp, transducer or pump opens the serial. On one screen sit the board revision, the sensor and ADC lots, the loaded firmware image and each bench calibration reading. No phone call to the factory floor is needed, and the quote names the correct part.
What goes wrong before the software.
How the work flows through it, step by step.
- 1
Enquiry and order
A laboratory or distributor order is entered with model, option codes, printer and cart accessories, and bench capacity then sets the delivery date promised to the buyer.
- 2
Board and sub-assembly
Boards and sub-assemblies are built in house or received by lot, then issued to the unit against the current revision of the bill. Reflow and in-circuit test reports stay attached to each board. Reports stay with the board.
- 3
Build and firmware
The technician assembles the unit, fits the optics and pump, and flashes the firmware image, while serials of every board, optical bench and pump are recorded as they go in.
- 4
Heat run and calibration
The unit sits in the heat chamber for the burn-in hours its model calls for, and faults are logged as they appear. Calibration readings are then taken against a named reference gas, check weight or thermometer. They are saved to the serial, so drift stays visible.
- 5
Final test and dispatch
The final test sheet is signed by the test engineer, and manuals, power leads and accessories are packed against the option codes on the order. The delivery note carries the serial.
- 6
Installation and service
At the hospital or laboratory the installer records mains earthing, bench levelling, a trial run on a control sample and the day warranty begins. Each later firmware flash and swapped pump, lamp or probe lands on the same serial. Nothing is keyed twice.
What is inside.
Every module can be switched on, left out or changed to match how your team already works.
The business modules it is built from.
Each one is also available on its own, or inside a system built for you.
- Bill of Materials
Boards, optics, pumps and enclosures sit in a bill with revisions, and a change notice lists the units still in build that it touches.
- Batch and Serial Tracking
Boards, sensors and displays are issued by lot and attached to the serial of the unit that received them, whichever bench built it.
- Job Work Management
Kits sent to a board assembler are tracked out and back, and the lot data returned is saved to the finished boards. Missing reels are obvious.
- Work Order Management
One work order builds one instrument, and the technician records every step, the firmware image flashed and the parts fitted, so the finished unit carries its full build sheet.
- Quality Control
Reference readings, tolerances and the standard used are saved on the serial, and a failed point holds the unit before final test.
- Fixed Asset Register
Calibration standards and bench tools are listed with due dates, so an expired cylinder or check weight cannot slip into a calibration sheet unnoticed by the test engineer.
- Service Reports and Proof of Visit
The installer completes the site checklist on a tablet, and the report is stored under the instrument serial together with the warranty start date and the trial run result.
- Asset AMC Tracking
Warranty and maintenance cover is held by serial, so each visit and replaced part links to the unit and the cover it falls under.
How we would put it in.
Setup, data migration, integrations and anything built on top.
One system, each person sees their part.
For production
Open the build, read the bill and revision, flash firmware and record the serial of every critical board, with rework on a fitted pump noted against the same unit.
For test and calibration
Run burn-in, enter calibration readings against the named standard and sign the final test sheet, while a failed point stays visible to the next shift on the bench. The next shift sees it.
For quality
Trace a PCB lot to its serials, release engineering changes and watch the due dates of reference standards, while approvals remain with you.
For field service
Log installation checks and visits. Read the build history of the unit before the drive to a hospital or laboratory, including every earlier pump or lamp swap.
For spares and dispatch
Quote spares by fitted revision, pack accessories and print delivery notes carrying the serial, so the reagent pack ships for the analyser it was ordered for.
The numbers the owner asks for.
- Units in build, burn-in, calibration and final test
- Firmware versions in the installed base
- Boards and sensors by lot against serials
- Calibration results outside tolerance
- Warranty expiry by customer
- Service visits by model and fault
- Spares sold by revision
Who this is built for.
- Makers of laboratory analysers
- Manufacturers of ECG and patient monitoring units
- Producers of ultrasound and imaging equipment
- Makers of point-of-care testing readers
- Firms that assemble diagnostic instruments for other brands
When it is not the right choice.
- A distributor that imports and installs instruments but builds none, whether analysers or monitors, will find a service desk and maintenance contract tool closer.
- Makers of implants will find Orthopaedic Implant Manufacturer Management Software closer.
Adapted to your business before it goes live.
You are not handed a login and left to it. The product is set up around your records, your people and the tools you already use.
Works alongside
- Test bench exports
- Barcode and label printers
- SMS
- Accounting export
Questions owners ask before a demo.
Can burn-in results be stored on the serial?
Yes. Hours, faults and retests are saved against the unit, with the heat chamber and technician named, so a unit that restarted its run shows both attempts side by side. Nothing is overwritten.
Does it track firmware updates in the field?
Yes. When a service engineer flashes a later image in a ward or laboratory, the date, the version and the engineer’s name go into the serial history.
Can contract assembly be recorded?
Yes. Kits sent out and boards returned are tracked, and the assembler’s lot data and in-circuit test report are saved to each board.
Can we quote the right probe or lamp?
Yes. The desk reads the revision fitted to that serial, so it picks the transducer, lamp or pump that really matches the unit in the customer’s room.
How are calibration standards controlled?
Each standard has a record with its due date, and a warning appears when a calibration sheet cites a cylinder, weight or thermometer that has lapsed.
Can installation reports be filled on a tablet?
Yes. The installer fills the checklist in a phone or tablet browser on site, and the finished report attaches to the serial with its photographs.
What does the software not do?
It does not approve devices or certify records. Your quality and regulatory staff decide what is recorded and how a unit is released.
What shapes the scope and the quote?
Users, sites and set-up work shape the scope. Share your requirements first, with the models and sites involved, and a written quote follows. Share your requirements and a quote follows.
Can the installed base be loaded?
Yes. Serials already shipped, their customers and warranty dates are keyed in from your old spreadsheets and service job files before go-live, so the first visit already finds a history.
Who maintains templates?
GullySystem staff adjust test sheets, bills and print formats when you ask for a change, and your quality lead approves it first.
Wondering what it would cost? Share your requirements and an engineer will come back with a scope.
Businesses that use this.
See Diagnostic Equipment Manufacturer Management Software with your own data.
Tell us how you run things today. We’ll show you the parts that matter to you and say plainly what would need changing.
- No obligation
- A reply within one business day
- Your details stay private
Start with your requirements
Seven short steps that tell us what you need. An engineer reads them before getting in touch.
Share your requirements