Skip to main content
GullySystem

Test menu and methods for an environmental laboratory

The test menu lists every method an environmental laboratory offers, by parameter and matrix. Each entry carries its units, detection limit, holding time and price. Orders, quotes, bench lists and certificates all read from it, so a change made once reaches every new sample. Laboratory managers and quality managers keep it current.

What each method entry holds

A method entry is one test, written the way the laboratory runs it. It names the parameter and the matrix, then carries the numbers that other features depend on. Staff do not retype these into each order. They choose the test.

Parameter, matrix and method

Each entry names the parameter, such as nitrate or total suspended solids, the matrix it applies to and the method reference used. The same parameter in water and in soil is two entries. Nothing is shared by accident.

Units and detection limits

The reporting unit and the detection limit for each parameter sit with the method. The certificate reads them from here, so it shows the same unit and limit that the analyst worked to. Both are edited in one place.

Holding time for each method

Each method carries its own limit between sampling and analysis. The holding time is entered as your method states it, and the bench list counts from the collection time. Samples nearing the limit rise to the top. The clock starts at collection.

Price and quote wording

Each test has a price, which quotes and invoices read. A price can differ by matrix. The wording shown to a client sits beside it, so a quote reads in the laboratory’s own terms. Price is held per test.

How the test menu is used week to week

The menu is read constantly and edited rarely. The moments below show it in use, from a first quote to a batch sheet to an audit. Each one is a person in the laboratory looking up a single entry before acting.

Quoting a new client

A client asks for a metals panel on wastewater. The manager selects the tests from the menu by matrix, and the prices come with them from the same entries. A quote is ready before the call ends.

Adding a method after training

The laboratory starts offering a new parameter once the analysts are trained. The quality manager adds the entry with its units, detection limit and holding time, and the manager sets a price. It then appears on new orders.

Choosing the right entry

An analyst opens a batch and finds the same parameter listed for water and for soil. The sample’s own matrix selects the entry, so the analyst runs the method written for that matrix. Choice is not left to memory.

Retiring an old method

A superseded method is withdrawn from the menu. New orders can no longer select it, and samples already booked against it are handled as the manager decides. The old entry remains visible against past work. History is not rewritten.

Who maintains and who relies on the menu

Few people edit the menu, but everyone relies on it. Four roles touch it in different ways. Access is set at implementation, so the right people can edit and the rest can only read.

For the laboratory manager

The manager owns prices and the list of what is offered. New tests are added when the laboratory can run them and withdrawn when it cannot. Revenue by test is read against the menu. Prices are the manager’s call.

For the quality manager

The quality manager owns the method details: units, detection limits and holding times. An edit carries the name of the person who made it, and audits ask when a limit changed and who agreed. Every edit is attributed.

For analysts at the bench

Analysts read the entry for the method they run and see the unit and holding time on the bench list. They do not edit it. A query about a limit goes to the quality manager.

For clients ordering work

A client placing an order through its login picks tests from the menu offered for its matrix. The client sees test names, and the laboratory decides whether prices are shown. Detection limits appear on the certificate.

Decisions to settle before the menu is loaded

Four decisions determine how clean the menu is on the first day. A messy menu produces messy quotes and certificates. Spend the time here, and the later features follow from it without rework.

Who may edit a method

Limit editing to named people. A detection limit or holding time changed by mistake alters every new result that reads it. Price edits may sit with the manager and method edits with the quality manager.

What the menu leaves out for Test menu and methods

Decide which tests are offered only on request, such as work sent to a partner laboratory and priced case by case. Method documents and validation files stay in the document store, not in the entry. Keep the entry to the figures.

How your test list comes across

GullySystem loads the test menu from your current sheets or software. Decide whether to clean it first. Duplicate parameter names, mixed units and out-of-date prices are easier to fix before loading than after it is live.

Which report matters first for Test menu and methods

Pick the first menu view to build. Revenue by client, matrix and test shows which entries earn their keep, while turnaround by method shows which entries cause delay. One of these will guide your first clean-up.

How the menu feeds quotes, batches and certificates

Several features read the test menu during a sample’s life. A quote takes the price, an order takes the test, the bench list takes the holding time and the certificate takes the unit and detection limit. Each reads the entry as it stands. Edit an entry, and the next sample reads the new values.

  • Prices go to quotes and invoicing
  • Tests ordered feed sampling schedules and bottle lists
  • Holding times drive the bench list from receipt
  • Units and detection limits reach result entry
  • Method choices appear on analytical batches

Where the test menu stops

The menu stores what the laboratory has decided to offer. Validation is a separate job. It does not validate a method, set a detection limit or confirm that a method suits a matrix. Those judgements rest with the quality manager, the method documents and any accreditation body. Prices and tax treatment on invoices are for the owner and the accountant. A laboratory with a short fixed list may manage with a printed price sheet.

FAQ

Frequently asked questions

Can one parameter have different methods for different matrices?

Yes, each is its own entry. Nitrate in drinking water and nitrate in soil extract use separate methods, so each has its own unit, detection limit and holding time. The matrix on the sample picks between them.

What happens to open samples when a limit changes?

That is the quality manager’s decision. An edit applies to new work from the time it is made, and any sample already in a batch is handled as the manager directs. The edit carries a name and a time.

Can prices differ for each client?

Prices sit with the test. A rate agreed with one client is a matter for the quote and the billing terms on its record. Quotes use the rate that applies, and your staff confirm what a client was promised.

How are new methods added?

A named person adds an entry with the parameter, matrix, method reference, unit, detection limit, holding time and price. After that it appears on new orders and quotes alike. GullySystem staff can add entries on request.

Does it hold the method documents themselves?

The entry holds the figures other features read. Method write-ups, validation files and training records belong in the document store or your quality system. The entry can name the document, so analysts know where to look.

Where it fits

How this feature fits the system.

Environmental Testing Laboratory Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.

Sampling schedules

Each field round is placed against the samplers who will drive it, with the sites, bottle sets and visit dates visible to the whole team.

Technician Scheduling

Analytical batches and controls

Every sample receives a laboratory number and travels in a batch, so any result can be followed back to its bottle, analyst and run.

Batch and Serial Tracking

Sample receipt and labelling

Labels printed at the receipt desk carry the laboratory number for the bottle and each aliquot drawn from it.

Barcodes and Labels
Talk to us

Tell us what you need.

Tell us what your team does today, where work gets stuck and what you want to change.

What happens after you share your requirements

  1. We review your brief and the systems you already use.
  2. We clarify the workflow, missing information and the work to consider first.
  3. The proposed scope sets out the deliverables, responsibilities and dependencies.
  4. Review the scope and commercial terms before deciding whether to proceed.

Start with your requirements

Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.

Share your requirements