Skip to main content
GullySystem
Manufacturing · Power Distribution Equipment Maker Software

One record for distribution transformers, boards and ring main units.

One record carries the tender, the quoted loss limits, drawing approvals, core steel and copper stock, unit routing, routine tests, witness calls and dispatch for each unit. Each unit has a serial number. Design office, stores, winding shop and test bay all see the same unit, and the buyer’s inspector is booked against it before the oil goes in.

  • Product families, routings and test sheets set up as you build them
  • Open orders, stock and unit history migrated
  • Changes to routings and templates handled by GullySystem staff when asked

Makers of distribution transformers, feeder pillars and ring main units get one place for tenders, drawings, core steel (CRGO) and copper stock, build routing, routine tests and witness calls. Each unit has a serial number. That number is tied to its core lot, its coils, its oil lot and its test report, so a question years later has one answer.

Where it breaks today

What goes wrong before the software.

Loss limits are promised but not followed

The tender states no-load and load loss limits in watts, yet the CRGO lot and copper weight behind a unit are never linked to the loss the test bay measures. Nobody checks. The gap surfaces at the buyer’s acceptance test, long after the tank is filled with oil and sealed, and the whole unit may need stripping.

Material is drawn for many units at once

Silicon steel coils and enamelled copper strip leave stores against several orders in one week, issued on a handwritten slip. Nobody can say what one 500 kVA unit actually consumed, so costing becomes a guess that the next tender repeats. Margins thin without anyone noticing.

Inspector visits are wasted

A utility inspector arrives for a witness test while the unit is still in the vapour phase drying oven, because the date lived in a desk diary. The trip is wasted, and the buyer is left annoyed.

Drawing comments overlap with cutting

The shop starts core cutting before the utility returns its final comments. Laminations are scrapped, the stack is cut again, and a week of mitred steel ends up in the scrap bin beside the slitting line.

Plates and reports separate

A rating plate is stamped from one list and the test report is printed from another, and the mismatch shows up at the buyer’s yard. The trailer is already unloaded.

Rewinding jobs mix with new builds

Repair units arrive beside new transformers and share one notebook with them, so neither gets a serial history, and a failed coil cannot be traced to its earlier rewind. The same inter-turn fault returns.

How it runs

How the work flows through it, step by step.

  1. 1

    Tender

    A tender arrives with rating, voltage ratio, vector group such as Dyn11, loss limits and delivery terms, and the offer is priced from core, copper, oil and tank. The quoted losses are stored with it.

  2. 2

    Drawing approval

    The design office issues general arrangement and core drawings, and every buyer comment is logged round by round until the utility signs. Only the approved revision goes to the shop floor. A draft never does.

  3. 3

    Materials

    Silicon steel, winding wire, oil and fittings are reserved for the order, then issued against units as the core room and winding shop ask for them. A shortfall in kraft paper or bushings shows early.

  4. 4

    Build

    Units pass through core stacking, winding, drying, tanking and oil filling, while boards and pillars follow sheet fabrication, busbar fitting and wiring instead. Each step is signed off by its supervisor.

  5. 5

    Test and inspection

    Routine tests are recorded against each serial number, and the buyer’s inspector is booked for any witness test the contract demands on that rating. The outcome is saved with the unit, including the loss figures read at the test bay and the inspector’s name.

  6. 6

    Dispatch

    Rating plates, test reports and packing lists are matched before the trailer is loaded, and nothing leaves with a mismatch. The invoice then follows the order.

Modules

What is inside.

Every module can be switched on, left out or changed to match how your team already works.

Tender pricing and loss commitments

Price a unit from core steel, winding copper, oil and tank, and keep the no-load and load loss limits quoted to the buyer beside each tender revision.

Drawing approvals

Follow each drawing through the buyer’s comment rounds, so only the approved revision reaches the core cutting line and the CNC cut-to-length machine. No lamination stack is cut to a stale sheet.

Core steel and winding wire stock

Hold CRGO coils and winding wire by lot and weight, and book offcuts from the slitting line to the unit that used the coil. Cost and traceability agree.

Unit routing

Show where each unit stands, whether at core stacking, LV and HV winding, vapour phase drying, tanking, oil filling or board fabrication.

Coil and winding records

Record every coil wound with its conductor size, number of turns, kraft paper insulation and weight, then name the unit it went into.

Oil and fittings

Track transformer oil by drum or tanker lot with its breakdown voltage reading, and issue bushings, tap changers, Buchholz relays and radiator fittings against the unit that carries them. Every fitting belongs to a unit.

Routine test reports

Store ratio, winding resistance, insulation resistance, no-load loss and load loss readings by serial number, and flag any reading above the quoted limit before the unit moves.

Inspection call register

Book the buyer’s witness test against the unit. The inspector’s name, the date and the result stay on the dispatch file, ready for the buyer’s store officer to check at receipt.

Serial plates and dispatch

Print rating plate data from the approved specification, then match plates, reports and packing lists before the consignment is loaded on the trailer.

Repair and rewind jobs

Units returned for repair or rewinding follow their own route with their own history, and each is linked to the original serial when it is known.

Solutions inside

The business modules it is built from.

Each one is also available on its own, or inside a system built for you.

  • Quote & Proposal Management

    A tender is priced from core, copper, oil and tank, and the loss figures quoted in the offer stay with each revision for later comparison against the test bay.

  • Bill of Materials

    Each rating has a bill listing core steel, winding wire, kraft paper, tank and fittings, so stores can reserve materials before the first lamination is cut.

  • Work Order Management

    A unit’s work order follows core stacking, winding, drying, tanking and oil filling, and each supervisor closes his own step at the bay as it finishes.

  • Quality Control

    Ratio, resistance, insulation and loss readings are entered per serial number, and a unit outside its limits is held at the test bay before dispatch.

  • Batch and Serial Tracking

    Each unit’s serial links to its core lot, coil records and test report, and the rating plate data is printed from that same record.

  • Project Document Management

    Drawings and buyer comments are filed against the order, and only the approved revision reaches the shop floor, so no core is cut to a draft.

  • Stock Tracking and Alerts

    Silicon steel and winding wire are tracked by lot and weight, with a warning raised when a coil runs low for the orders in hand.

  • Job Work Management

    Units sent out for outside processes, or returned for rewinding, travel on their own job route and come back against the original record, with their history intact.

Services

How we would put it in.

Setup, data migration, integrations and anything built on top.

Who uses it

One system, each person sees their part.

For design engineers

Prepare drawings and log buyer comments round by round. Release approved revisions to the core room only after the utility has signed, because a draft never leaves the office.

For tender estimators

Price units from the bill of core, copper and oil, store the loss limits quoted, and follow each tender through to its outcome and the buyer’s purchase order.

For winding and assembly supervisors

See which units wait for coils, drying or tanking. Record each step as it finishes, with the bay, the date and the supervisor who closed it, so the schedule stays honest.

For the test bay

Enter ratio, resistance, insulation and loss readings per unit, then mark it passed or held, with the vector group check on the same sheet as the megger reading. No loose paper.

For dispatch staff

Match plates, reports and packing lists before a consignment leaves the yard, because a mismatch holds the trailer at the weighbridge until someone corrects the plate. Check twice.

Reports

The numbers the owner asks for.

  • Units by build stage and by order
  • Quoted against measured losses per unit
  • CRGO and winding wire consumed by order
  • Witness calls booked with outcomes
  • Drawings awaiting buyer approval
  • Rewind jobs open by customer
Good fit

Who this is built for.

  • Makers of distribution transformers built to utility specifications
  • Manufacturers of ring main units and feeder pillars
  • Plants building distribution boards and metering panels
  • Workshops that both build and rewind transformers
  • Suppliers who sell by tender to utilities and large contractors
Honest answer

When it is not the right choice.

  • An electrician who assembles small boards on site can work from drawings and notes, and has no use for a serial register.
  • A shop whose output is mainly lineups of withdrawable panels should look at Switchgear Manufacturer Management Software, which follows that kind of build more closely.
Made to fit

Adapted to your business before it goes live.

You are not handed a login and left to it. The product is set up around your records, your people and the tools you already use.

Product families and routes

Transformer, pillar and board routes are set up with the steps your plant really uses, from core stacking and winding to oil filling. A ring main unit never inherits a drying step.

Test sheets

Routine test sheet layouts and limits are set with your quality staff, who review each sheet before it is used on a live unit.

Material catalogue

Steel grades, wire sizes, oil types, bushings and tap changers are loaded together with their usual suppliers and bin locations.

Opening records

Orders in hand, stock on hand and serials already issued are imported from your existing files, then checked against the bin cards by the storekeeper.

Currency and tax

Each buyer’s country decides the currency on the offer and the tax lines on the invoice, and both are set once for that buyer.

Works alongside

  • Email
  • WhatsApp
  • Accounting export
  • Label printer
  • Drawing file storage
Common questions

Questions owners ask before a demo.

Can the promised loss be checked against the test result?

Yes. The tender stores the loss limits and the routine test enters the measured values beside them. Any unit above a limit is flagged before it reaches the dispatch bay.

How is core steel tracked?

Coils are received by lot and weight and consumption is booked to each unit, so the lot number shows on the unit’s record beside its winding sheet.

Can it follow oil filling?

Oil is issued by quantity against the unit at the filling step, with the drum or tanker lot and its breakdown voltage noted beside it.

Does it manage the buyer’s witness test?

Yes. A call is booked against the unit, and the inspector’s name and result are saved into the dispatch file for the buyer’s store.

Can pillars and boards use the same system?

Yes. They follow a shorter route of sheet fabrication, busbar fitting and wiring, and they share the same serial register and test records as the transformers.

How are repairs recorded?

A returned unit opens a repair job with its own steps and its own history, and the dates are written on it. The original serial is linked if the unit is known, so an earlier rewind is visible to the next shift.

What decides the price?

Users, product families and test sheets set the figure. We walk through a sample transformer record with you and your estimator, then put the price into a written proposal.

Can we keep drawings in the system?

Yes. Every comment round stays attached to the order beside its drawing, and the approved revision is easy to spot among the superseded ones.

How do we bring in existing data?

Core steel, winding wire and units in progress are imported from your spreadsheets. Your design engineers then compare loaded stock with the bin cards, line by line, before any real order goes in.

Does it certify our products?

No. It stores your records and reports. Compliance with IEC 60076 or a utility approval stays with your quality and regulatory team, who sign the test certificates.

Wondering what it would cost? Share your requirements and an engineer will come back with a scope.

Book a demo

See Power Distribution Equipment Maker Software with your own data.

Tell us how you run things today. We’ll show you the parts that matter to you and say plainly what would need changing.

  • No obligation
  • A reply within one business day
  • Your details stay private

Start with your requirements

Seven short steps that tell us what you need. An engineer reads them before getting in touch.

Share your requirements