Skip to main content
GullySystem

End-of-line test and certification for vehicle plants

The end-of-line test captures roller brake, headlamp aim, emission, camber, toe-in and shower leak readings against the limits on your test sheet, lane by lane. A test certificate is issued only when every reading passes. One failed reading means a unit cannot be released to the yard.

What the end-of-line test keeps for each unit

A unit reaches the end of the line complete but unproven. Your test sheet for its model turns that into a set of readings. Each one is kept against the unit, lane by lane. It belongs to your plant. Four kinds of record come out of it.

Readings by test lane

Roller brake, headlamp aim, emission, camber, toe-in and the shower leak result are each recorded in the lane that measures them. A reading is entered once. Nobody copies it from a bench ticket or retypes it at a desk later.

Limits from your test sheet

Each reading is compared with the limit on the test sheet for that model. It follows your own procedure, the testers you own and the certificate your market asks for. Pass or fail shows beside the reading.

Emission and smoke readings

The emission reading sits on the same record as brakes and lamps. A diesel unit adds its smoke opacity. A petrol unit does not. Each variant’s sheet asks only for what that unit needs, and nothing more.

The test certificate

A certificate is issued only when every reading on the sheet passes. It carries the vehicle identification number and the readings behind it. One failed reading means no certificate. Release to the yard is refused.

A shift in the end-of-line test bay

The bay is the last place a fault can be found before a dealer finds it. Testers move each unit through the lanes in turn. These four moments show the feature at work. Each one ends in a pass, a fail or a certificate.

A unit meets the brake rollers

The tester drives the unit onto the rollers and runs the brake test. The roller brake readings are recorded against the unit. Where the bench can send readings they arrive on their own. Otherwise the tester keys them.

Headlamp aim and toe-in are read

Next come the headlamp and alignment lanes. Headlamp aim is recorded first, then camber and toe-in. Each value is set against the limit on that model’s sheet. A toe-in result outside its limit fails the unit.

The shower finds a leak

In the water booth a door seal leaks. The shower result is recorded as a fail. It goes to the rework bay with the lane and the reading on its entry. It cannot reach the yard.

A passed unit is certified

Every reading on the sheet is within its limit. The certificate is issued and attached to the unit’s record. The unit moves to the yard. Dispatch now sees a finished car that can be allocated to a dealer.

Who sees the test results and what each sees

Testers write the readings. Others depend on them. The yard takes only certified units. Dispatch works from the certificates. Quality reads the results as a whole. Each role sees the same unit through its own need.

Testers working each lane

Testers see the sheet for the unit in front of them and record each reading in their lane. A reading outside its limit shows as a fail. They do not decide to waive it. They pass the unit to rework.

Quality managers reading first-pass results

Quality managers see end-of-line first-pass results by unit and test lane. A lane that fails more units than the others stands out. They also hold suspect lots. They manage the rework bays that the failures feed.

Supervisors with a failed unit

Supervisors see which units failed, in which lane and by how much. They send the unit to rework. They watch it return for a retest in the lane that failed it. The retest result lands on the same entry.

Dispatch clerks checking certificates

Dispatch and sales administration work from certified units. Before a car is allocated to a dealer or booked onto a carrier, its certificate is already on the record. Nobody has to walk over and ask the test bay.

Decisions to settle before test sheets go live

Your sheet is the heart of this feature, so its rules need agreeing first. Settle these four with quality, the testers and dispatch before the first unit is certified. Each is a short conversation.

Who may amend a test limit

Decide who in your plant approves a change to a limit. You then ask GullySystem staff to make it. The old sheet stays on file. An earlier unit can still be judged against its own limit.

Which readings each model needs

A hatchback, an estate, a van and a light truck may need different readings. Choose the tests each sheet carries. Choose which lanes run them. Do it model by model, with quality, before any unit is tested.

How test sheets are entered

Your current test procedure, the limits for each model and the certificate your market asks for are entered to match. Your quality manager reviews them first. Results on paper from earlier units stay filed where they are now.

The test report to read first

Begin with end-of-line first-pass results by unit and test lane. It shows which lane is catching the failures. Read it after the first batch of units. Then set it beside the rework causes by station, in the same meeting.

How the end-of-line test connects to the plant

This test is the last gate before the yard. It takes finished units from the assembly stations and hands failures to rework. Passed units go on to dealer allocation and dispatch. These are the links quality and dispatch use. Each is a record the next feature reads.

  • Station checks complete the unit before it reaches the test
  • Rework and defect tracking receives every unit that fails
  • Variant and model decide which test sheet applies
  • Dealer allocation takes only certified units into the yard
  • Warranty queries return to the stored readings and certificate

Where end-of-line testing stops

This feature compares readings with your limits and issues the certificate on a full pass. It measures nothing itself. Calibrating the roller brake bench, the headlamp tester and the emission analyser stays with your quality staff. Type approval and any legal conclusion stay with your compliance staff and an adviser. A garage building one kit car a month can test on a paper sheet.

FAQ

Frequently asked questions

Can a unit with one failed reading be released?

No, one failed reading blocks it. A certificate is issued only when every reading passes. Without one, a unit cannot be released to the yard. The unit goes to rework, with the failed reading on its entry.

What happens to a unit that fails the shower test?

It goes to the rework bay. The entry names the lane and the reading. Rework then adds the defect code, the cause and the fix, such as a reseated door seal, and the unit is retested.

Does the test sheet differ by model?

Yes, each model has its own limits and its own list of readings. A diesel estate asks for smoke opacity. A petrol hatchback does not. Each sheet follows the variant on the build order, so no unit is asked for a test it does not need.

How is the test certificate issued?

The system issues it when every reading on the sheet passes. It carries the vehicle identification number, the readings and the date. Its layout follows what your market asks for. That is agreed with you during set-up.

Is the first-pass result kept after a retest?

Rework records the retest result on the entry. The first-pass report counts units that passed on the first attempt apart from those that were retested. A lane that keeps failing cannot hide behind its retests.

Where it fits

How this feature fits the system.

Auto Manufacturer Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.

Variant parts master and bills of materials

Each model, trim, engine and market has its own bill, from subframe to wiper arm. A build order reads only the parts that its variant needs.

Bill of Materials

Build orders and slot planning

Dealer orders become build orders in weekly slots. Short axles, seats or glazing for a slot show before the order is released to stores.

Production Planning

Station checks and torque records

Each unit carries a work order through body shop, paint and trim lines. An operator closes a station only after its nutrunner checks are recorded.

Work Order Management
Talk to us

Tell us what you need.

Tell us what your team does today, where work gets stuck and what you want to change.

What happens after you share your requirements

  1. We review your brief and the systems you already use.
  2. We clarify the workflow, missing information and the work to consider first.
  3. The proposed scope sets out the deliverables, responsibilities and dependencies.
  4. Review the scope and commercial terms before deciding whether to proceed.

Start with your requirements

Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.

Share your requirements