Result entry and review for laboratory batches

Result entry and review is where bench work becomes approved data. Analysts enter results or import them from an instrument file, derived values are calculated, and the batch goes to a named reviewer. The reviewer sees results, controls, instrument and analyst together, then approves the batch or returns it with a reason.

What each result entry records

A result is more than a number. Each entry keeps the value, the unit, the method and the person who entered it, and it keeps how the value was reached. Reviewers see what was done without asking anyone at the bench.

Raw and reported values

Each result holds the value as read from the instrument and the value to be reported, with the unit from the test menu. Where the two differ, the working is shown on the line. No part is hidden in a spreadsheet.

Derived values and dilutions

Where a result is calculated, such as from a dilution factor or a sum of parts, the derived value is worked out from the entered figures. The inputs stay on the line. A figure changed later changes the result.

Results below the detection limit

A value below the detection limit is entered as such and is reported against the limit held in the test menu. It is not a measured number. Certificates read it from the same entry, so the report agrees with the bench.

Entry source and edits

Each result shows whether it was typed or imported from an instrument file, who entered it and when. An edit after entry is attributed to the person who made it. Typed or imported, the source is shown.

Entering and reviewing a batch of results

A batch moves from the bench to the reviewer and sometimes back again to the bench. The moments below follow one batch through that loop, from the first imported file to the final release. Each is a person reading the same page.

Importing an instrument file

An analyst loads the export from the ion chromatograph into the batch. Results appear against the laboratory numbers named in the file, so nobody retypes the lines by hand. Unmatched lines are listed. The analyst resolves each one.

Keying results from the bench

Where there is no file, results are typed in. A pH value from a handheld meter goes onto its line with the unit already shown, and the analyst works down the list. The unit never needs to be typed.

Reading the batch as a reviewer

Opening one page, the reviewer sees results, controls, the instrument and the analyst. A blank and a spike inside their ranges let the review move quickly, while one outside is marked. No second file is needed.

Returning a query to the bench

A reviewer doubts a nitrate value after seeing a duplicate disagree. It goes back to the analyst with the reason written on it, and the analyst reruns or explains. The batch comes back for a second look.

Who enters, reviews and relies on results

Entry and review are separate jobs. Four roles work around them, and each sees what that role needs to do its own job. Each batch has a named reviewer, chosen under your approval rules.

For analysts entering results

Analysts see the batches assigned to them, the methods and controls required and the instruments that are in date. They enter or import results and send the batch on. Returned batches show the reviewer’s reason.

For the quality manager

The quality manager reads corrections and approvals, each attributed to a person. For a given batch, the record names both the analyst and the reviewer. That separation matters at an audit. Both names are on file.

For the laboratory manager

Batches waiting for review and batches returned appear on the manager’s screen beside the queue by analyst. A pile-up on one reviewer shows. Work can be directed to another named reviewer when the first is away.

For clients awaiting data

Through its own login, a client sees whether a sample is in analysis or finished. Results reach the client on the signed certificate, after approval by the named reviewer. Draft numbers stay inside the laboratory.

Decisions to settle before review begins

Four decisions set how much weight the review step carries. Take them with the quality manager and the person who will review the first batches. Make them early. Their answers are written into the set-up.

Who may approve a batch

Name the people allowed to approve, by method or by matrix. Nobody should approve work they entered themselves. Say whether a second reviewer is needed for particular parameters such as metals. Write the rule down.

What a reviewer sees first

Decide what sits at the top of the review page. Controls out of range, then results near a client’s limit, is one order. Another puts the instrument and calibration status first. Choose one order for every batch.

How imports are matched

Where an instrument writes a file, an import is built for it. Decide which instruments come first and what the file must carry for a line to match. Handwritten bench sheets keep manual entry. Each instrument is scoped separately.

Which report matters first for Result entry and review

Pick the first review view to build. Batches awaiting review shows the queue, and reports issued, corrected and withdrawn shows the outcome. Decide which one the manager needs on the day the first batch is released.

How review connects to certificates and batches

Result entry sits between the batch and the certificate. It takes samples, controls and instrument links from the analytical batch and works out derived values. Approved results are handed to the limit check and the certificate. A returned batch goes back. The reason travels with it.

  • Takes samples and controls from analytical batches
  • Takes units and detection limits from the test menu
  • Imports instrument files where a connection is built
  • Hands approved results to certificates and limit checks
  • Updates sample status for the client login

Where result entry and review stop

The review step records a decision. It does not make one. Whether a result is plausible, whether a rerun is warranted and whether a batch should be released are judgements for the reviewer and the quality manager. The feature cannot check an instrument’s raw data or replace the method. A laboratory that releases a few results a week may use a signed bench sheet.

FAQ

Frequently asked questions

Can two analysts enter results into the same batch?

Yes, where your method allows. Each line records who entered it, so a batch can carry entries from several analysts. The reviewer sees the names beside the lines and judges the batch as a whole.

What happens when a reviewer returns a batch?

It goes back to the named analyst with the reason written on it. It leaves the review queue and returns to the bench list. After a rerun or an explanation, it is submitted again. Nothing is released meanwhile.

Are derived values recalculated after a correction?

Inputs drive the derived value, so a corrected input changes the figure worked out from it. The change is attributed. It is shown to the reviewer. A correction made after approval needs approval again from the reviewer.

What if our instrument cannot export a file?

Then results are typed in. The units are already shown on the batch lines. Import is built only where an instrument writes a file, and it is scoped for each instrument. Typed and imported lines look alike to the reviewer.

Who is the reviewer for a batch?

A named person, chosen under your rules. Release waits until that person approves it in the system. The record carries the analyst’s name and the reviewer’s name for every batch that passes through the laboratory.

Where it fits

How this feature fits the system.

Environmental Testing Laboratory Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.

Sampling schedules

Each field round is placed against the samplers who will drive it, with the sites, bottle sets and visit dates visible to the whole team.

Technician Scheduling

Analytical batches and controls

Every sample receives a laboratory number and travels in a batch, so any result can be followed back to its bottle, analyst and run.

Batch and Serial Tracking

Sample receipt and labelling

Labels printed at the receipt desk carry the laboratory number for the bottle and each aliquot drawn from it.

Barcodes and Labels
Talk to us

Tell us what you need.

Tell us what your team does today, where work gets stuck and what you want to change.

What happens after you share your requirements

  1. We review your brief and the systems you already use.
  2. We clarify the workflow, missing information and the work to consider first.
  3. The proposed scope sets out the deliverables, responsibilities and dependencies.
  4. Review the scope and commercial terms before deciding whether to proceed.

Start with your requirements

Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.

Share your requirements