Test Master and Reference Ranges for Pathology Labs
The test master is the lab’s own catalogue. It decides what a report shows, how a value is flagged and which container a test needs. When the lab changes a kit or an analyser, the master is where the new range, unit or method is entered, and later reports follow it.
What each test holds
Setting these fields carefully once saves the desk and the bench from the same repeated corrections for years, since every order, label, flag and printout reads from this one place.
Profiles and packages
A profile bundles tests that are ordered together, such as a liver function test. A package groups profiles for a health check. Each can carry its own price on each rate list. Prices are held per rate list. A package can cost one amount for walk-ins and another for a corporate client, while the profile expands to the same tests on the worklist.
Who approves changes
Ranges and methods change when a lab changes its analyser or kit. A range edit is recorded with who made it and when. The lab’s pathologist approves the master before it goes into use. Signed reports are not changed. A dated approval gives a clear answer to a question months later, such as which range applied to a report in March. Nobody has to rely on memory.
Why ranges differ by age and sex
A newborn, a child and an adult do not share a normal haemoglobin. Studies of reference intervals find that most tests need age bands, and some need separate values for men and women. The lab is expected to set or check its own intervals, because the population, the method and the machine all move the numbers. Standards bodies such as CLSI publish guidance on how to define and verify them. The system holds what the pathologist decides and applies it to each patient by age and sex. Where a kit leaflet and the lab’s own verification disagree, the pathologist chooses, and that choice is entered once and applied from the date given.
- Age bands that match the lab’s method and population
- Separate values for men and women where it matters
- Pregnancy or other special ranges, if the lab uses them
- Critical limits that trigger a call to the doctor
When a kit or an analyser changes
A new kit can shift results a little, and a new method can change units. The test master is the one place where that change is entered. After it is approved, new reports follow the new range, and old reports stay as signed. Printing the method on the report helps readers who compare results from two labs. Some labs print the range and the method side by side so a doctor sees which one applied.
Questions for the pathologist before the master is built
A catalogue takes a day or two to check line by line, so ask these first. Bring the kit leaflets and the current printed report to the first session. Comparing the two on screen finds mismatches quickly, before any patient report is affected.
A week with the test master in a lab
A new kit arrives, a clinician asks about an unusual test, a report is queried. Each moment sends someone back to the same catalogue. Here is how that looks in a week.
Agree the evidence before signing off this part.
Use a representative scenario to decide what this part of the system must show and where review is still needed.
Approval
What needs fresh approval after a record is changed?
For “Approval”, change a material detail after approval during a scoped walkthrough. Agree the next responsible person and the evidence needed before the work can continue.
Background reading: ERPNext: approval transitions
When a kit or an analyser changes
What does one row mean before totals are combined?
Choose one period in “When a kit or an analyser changes” and compare it with the source records. Define the date basis and grouping before accepting a total that combines several kinds of entry.
Background reading: Microsoft: reporting grain and relationships
Frequently asked questions
Can we bring our current test list across?
Yes. The existing list is imported, then checked line by line with the pathologist before the first day.
Do you supply reference ranges?
No. Ranges come from the lab, its kits and its pathologist. The system holds and applies them.
Can a range be changed for new reports only?
Yes. An approved change applies to later reports, and signed reports are not changed.
Can one test have different ranges for different machines?
That is a scoping point. Tell us if the lab runs one test on two analysers with different intervals.
Can prices be set per test?
Each test, profile and package can carry a price on each rate list.
Who can edit the master?
The lab chooses. Every range edit is recorded with who made it and when.
How this feature fits the system.
Pathology Lab Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.
Sample collection and barcodes
A barcode prints for every container at collection, recording sample type and time, and the lab marks any rejected sample with a reason.
Barcodes and LabelsHome collection visits
Home collections are booked by area and time slot and assigned to a phlebotomist, and the front desk sees which samples have reached the lab.
Appointment SchedulingQuality control records
Technologists record daily control runs by test and machine, plot them against limits the lab sets, and note the action taken on a failed run.
Quality ControlTell us what you need.
Tell us what your team does today, where work gets stuck and what you want to change.
What happens after you share your requirements
- We review your brief and the systems you already use.
- We clarify the workflow, missing information and the work to consider first.
- The proposed scope sets out the deliverables, responsibilities and dependencies.
- Review the scope and commercial terms before deciding whether to proceed.
Start with your requirements
Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.
Share your requirements