Test Master and Reference Ranges for Pathology Labs

The test master is the lab’s own catalogue. It decides what a report shows, how a value is flagged and which container a test needs. When the lab changes a kit or an analyser, the master is where the new range, unit or method is entered, and later reports follow it.

What each test holds

Setting these fields carefully once saves the desk and the bench from the same repeated corrections for years, since every order, label, flag and printout reads from this one place.

Name and code

The name printed on the report and the short code the desk types.

Units and method

Units of measure and the method or analyser used, printed where the lab wants them.

Sample type and container

Which sample and tube the test needs, so the right barcode labels print.

Reference ranges

Normal ranges by age and sex, and critical limits where the pathologist sets them.

Profiles and packages

A profile bundles tests that are ordered together, such as a liver function test. A package groups profiles for a health check. Each can carry its own price on each rate list. Prices are held per rate list. A package can cost one amount for walk-ins and another for a corporate client, while the profile expands to the same tests on the worklist.

Who approves changes

Ranges and methods change when a lab changes its analyser or kit. A range edit is recorded with who made it and when. The lab’s pathologist approves the master before it goes into use. Signed reports are not changed. A dated approval gives a clear answer to a question months later, such as which range applied to a report in March. Nobody has to rely on memory.

Why ranges differ by age and sex

A newborn, a child and an adult do not share a normal haemoglobin. Studies of reference intervals find that most tests need age bands, and some need separate values for men and women. The lab is expected to set or check its own intervals, because the population, the method and the machine all move the numbers. Standards bodies such as CLSI publish guidance on how to define and verify them. The system holds what the pathologist decides and applies it to each patient by age and sex. Where a kit leaflet and the lab’s own verification disagree, the pathologist chooses, and that choice is entered once and applied from the date given.

  • Age bands that match the lab’s method and population
  • Separate values for men and women where it matters
  • Pregnancy or other special ranges, if the lab uses them
  • Critical limits that trigger a call to the doctor

When a kit or an analyser changes

A new kit can shift results a little, and a new method can change units. The test master is the one place where that change is entered. After it is approved, new reports follow the new range, and old reports stay as signed. Printing the method on the report helps readers who compare results from two labs. Some labs print the range and the method side by side so a doctor sees which one applied.

Update the range

Enter the new interval and the date it starts.

Check the unit

Confirm the unit has not changed with the method.

Approval

The pathologist approves before use.

Brief the bench

Tell technicians what changed and from when.

Questions for the pathologist before the master is built

A catalogue takes a day or two to check line by line, so ask these first. Bring the kit leaflets and the current printed report to the first session. Comparing the two on screen finds mismatches quickly, before any patient report is affected.

Which units does the lab print?

Pick one per test and keep it.

Which ranges apply, and from what source?

Labs use the kit leaflet and their own verification.

Which tests carry critical limits?

List them with the values.

Which profiles does the desk order most?

Build those first, so the first week is smooth.

A week with the test master in a lab

A new kit arrives, a clinician asks about an unusual test, a report is queried. Each moment sends someone back to the same catalogue. Here is how that looks in a week.

Monday kit check at the bench

The bench lead unpacks a new reagent lot and reads the insert against the master. If a unit or range differs, the change goes to the pathologist. Until it is approved, the old entry stays in force. Nothing changes by guesswork.

At the desk with an unusual request

A walk-in asks for a test the lab has not run before. The desk looks for a code, a container and a price in the master. A missing test is noted as a request, not guessed. The request is still on file.

Pathologist reviews a flagged value

A report comes back with a value flagged against the wrong age band. The pathologist opens the test, reads the range history and sees who edited it. The fix is made once and recorded. No other report is touched.

Month-end catalogue tidy

The lab manager scans the master for retired tests and profiles nobody orders. Those entries are switched off, not deleted. Old reports still open with the range that applied when they were signed. History stays readable.

Make an informed decision

Agree the evidence before signing off this part.

Use a representative scenario to decide what this part of the system must show and where review is still needed.

Approval

What needs fresh approval after a record is changed?

For “Approval”, change a material detail after approval during a scoped walkthrough. Agree the next responsible person and the evidence needed before the work can continue.

Background reading: ERPNext: approval transitions

When a kit or an analyser changes

What does one row mean before totals are combined?

Choose one period in “When a kit or an analyser changes” and compare it with the source records. Define the date basis and grouping before accepting a total that combines several kinds of entry.

Background reading: Microsoft: reporting grain and relationships

FAQ

Frequently asked questions

Can we bring our current test list across?

Yes. The existing list is imported, then checked line by line with the pathologist before the first day.

Do you supply reference ranges?

No. Ranges come from the lab, its kits and its pathologist. The system holds and applies them.

Can a range be changed for new reports only?

Yes. An approved change applies to later reports, and signed reports are not changed.

Can one test have different ranges for different machines?

That is a scoping point. Tell us if the lab runs one test on two analysers with different intervals.

Can prices be set per test?

Each test, profile and package can carry a price on each rate list.

Who can edit the master?

The lab chooses. Every range edit is recorded with who made it and when.

Where it fits

How this feature fits the system.

Pathology Lab Management Software: the parts that work with this feature, the trades that use it and the ways to put it in place.

Sample collection and barcodes

A barcode prints for every container at collection, recording sample type and time, and the lab marks any rejected sample with a reason.

Barcodes and Labels

Home collection visits

Home collections are booked by area and time slot and assigned to a phlebotomist, and the front desk sees which samples have reached the lab.

Appointment Scheduling

Quality control records

Technologists record daily control runs by test and machine, plot them against limits the lab sets, and note the action taken on a failed run.

Quality Control
Talk to us

Tell us what you need.

Tell us what your team does today, where work gets stuck and what you want to change.

What happens after you share your requirements

  1. We review your brief and the systems you already use.
  2. We clarify the workflow, missing information and the work to consider first.
  3. The proposed scope sets out the deliverables, responsibilities and dependencies.
  4. Review the scope and commercial terms before deciding whether to proceed.

Start with your requirements

Describe your current process, the people involved and the change you need. Start with the details you know; we can clarify the rest together.

Share your requirements